An Extended Study Regarding the Phenomenon of Optical Flicker and the Design Details of the Statistical Scale Designed by the Department of Electrical Engineering at the Higher Institute of Engineering Technology/Tripoli
Keywords:
Statistical analysis, Epilepsy in children, Muscle spasms, Epileptic seizures, Electromagnetic compatibility, Digital signal processorsAbstract
The phenomenon of light tremors causes severe anxiety, tension and headaches, and in some cases it may lead to epilepsy for those who are sensitive to this type of nerve stimulation, and it occurs due to continuous or almost continuous fluctuations in the intensity of lighting. It does not mean here single changes regardless of their intensity, but rather that change that has a pattern and nature of continuous stress in time and its effect is of a cumulative statistical nature. This stress is at its highest intensity when the frequency of these changes is 8.8 Hz. It is known that the electrical power of the incandescent lamp is proportional to the root mean square of the instantaneous value RMS of the voltage wave. Therefore, these voltage disturbances must be monitored, which appear as the delay of the voltage wave amplitudes. This type of disturbance occurs due to the operation of the voltage regulators of the synchronous generators or due to the constant change in the value of the loads on the network, especially non-linear ones. Due to the importance of this topic to human safety, the European type EN-60150 has set permissible values for the value of the coefficient of Pst which gives the probability of occurrence of tension due to light jitter, based on the measurement of the instantaneous value of the voltage wave for ten minutes, corresponding to the Plt coefficient which is calculated based on the first parameter as a geometric mean for two hours, European style EN-50160 sets the limits for weekday continuous measurement. The meter is a device that consists of several functional boxes that end with a statistical analysis. Accordingly, the International Electrotechnical Council has issued a standard pattern IEC61000-4-15 that describes the box diagram for a measure of the effect of the phenomenon of light disturbance on human behavior. In this research paper, design details not mentioned in the patterns were given, as well as a computer program on Matlab for a digital scale based on a design for the Higher Institute of Engineering Technologies/Tripoli
Downloads
References
CLC/TC 8X - System aspects of electrical energy supply 2019. EN 50160: Characteristics of the voltage (PQ) in public electricity supply networks.
Canadian Standards Association (operating as CSA Group) (link is external) 2021. IEC 61000-4-15: Electromagnetic compatibility (EMC) – Part 4-15: Testing and measurement techniques – Flickermeter – Functional and design specifications.
IEC 61000-3-3: Threshold values – limit of voltage changes, voltage variations and flicker in public low voltage supply networks for devices with a rated current < = 16 A per phase.
Photosensitive Epilepsy – symptoms – causes – treatment, webmd.com/epilepsy/guide/photosensitive-epilepsy-symptoms-causes-treatment
Photosensitivity and Seizures, epilepsy.com/learn/triggers-seizures/photosensitivity-and-seizures
Juvenile Myoclonic Epilepsy, epilepsy.com/learn/types-epilepsy-syndromes/juvenile-myoclonic-epilepsy
Arduino -Matlab based flickermeter Realization and verification according to IEC 61000-4-15 standard, 2018, LICEET 2018 (Libyan International Conference on Electrical and Technologies).
academia.edu/36190143/Arduino_-Matlab_based_flickermeter_Realization_and_verification_according_to_IEC_61000-4-15_standard
Hartman M., Hashad M., Wolski L., "Computerised flickermeter according IEC 61000-4-15 and IEC 1000-3-3 standards 5" International Conference Electrical Power Quality and Utilisation, Sept. 1999, Krakow, Poland.
Matlab, MathWorks, Flickermeter Simulator, mathworks.com/matlabcentral/fileexchange/24423-flickermeter-simulator
M. Türkuzan and Ö. Salor, "Realization of IEC flickermeter for different types of lamps," 2016 24th Signal Processing and Communication Application Conference (SIU), 2016, pp. 1653-1656, doi: 10.1109/SIU.2016. DOI: https://doi.org/10.1109/SIU.2016.7496074
S. Lodetti et al., "Sensitivity of modern lighting technologies to rapid voltage changes," 2018 18th International Conference on Harmonics and Quality of Power (ICHQP), 2018, pp. 1-6, doi: 10.1109/ICHQP.2018. DOI: https://doi.org/10.1109/ICHQP.2018.8378925
G. Wiczynski and P. Kuwaek, "Influence of Sampling Rate on Flicker Assessment by IEC Flickermeter Built-in AMI Energy Meters," in IEEE Transactions on Industrial Electronics, doi: 10.1109/TIE.2021.