Photovoltaic Distribution Generation Case Study of 30/11kV(Alskarait Substation)

Authors

  • M. I. Abozaed Faculty of Engineering, Renewable Energy Center, Misurata University, Misurata, Libya
  • A. A. Abohger The General Electricity Company of Libya (GECOL), Misurata, Libya

Keywords:

Alskerat (Misurata substation), Distribution Generation (DG), NEPLAN software, PVsyst software

Abstract

The Distribution Generation (DG), which is a new member of distribution systems, enhances system performance. The DG improves voltage profiles, reduces real power loss, increases the system capacity and reliability. It is intended to boost the infrastructure in an environmentally friendly manner in comparison to Conventional power sources. Achieving the aforementioned benefits requires installing DGs of appropriate capacity in appropriate location. The ultimate goal of this work is to meet expected load demands for the next ten years in Alskerat (Misurata substation) by means of a photovoltaic (PV) DG system. While PVsyst software was used to identify the type and number of PV modules and inverters, and  NEPLAN software has been used to analyze and simulate the work of the PV system. The current loads in the Alskerat power station are 18 MW and the expected loads for the next ten years will be approximately 38 MW calculated by load growth formula rate. The increasing of generating capacity of 20 MW was done by placing an electric power production station using renewable energies, which are the photovoltaic modules. The results of this attempt show an improved voltage profile of the grid and overcome to voltage drop problem while increasing load. From the results, the voltage drop that was addressed to the value 26.89 kV has been improved to a normal 30 kV after connecting the photovoltaic station. In addition, a cost-effect analysis in this work illustrates an advantage for PV systems over Conventional systems.

Downloads

Download data is not yet available.

References

. C. Budischak al. Cost-minimized combinations of wind power, solar power and electrochemical storage, powering the grid up to 99.9% of the time. journal of Power Sources, ScienceDirect, 2013, 225, pp. 60-74. DOI: https://doi.org/10.1016/j.jpowsour.2012.09.054

. A. Chambers, B. Schnoor, and S. Hamilton, Distributed generation: a nontechnical guide. 2001. PennWell Books.

. G. Pepermans al. Distributed generation: definition, benefits and issues. journal of Energy policy, ScienceDirect. 2005, 33(6), pp. 787-798. DOI: https://doi.org/10.1016/j.enpol.2003.10.004

. T. Ackermann, , G. Andersson, and L. Söder, Electric power systems research- ScienceDirect 2001. Distributed generation: a definition., 57(3), 195-204. DOI: https://doi.org/10.1016/S0378-7796(01)00101-8

. E. Caamaño Martín, , H. Laukamp, M. Jantsch, T. Erge, J. Thornycroft, H. De Moor, and B. Gaiddon, Interaction between photovoltaic distributed generation and electricity networks 2008. Progress in Photovoltaics: research and applications, 16(7), 629-643. DOI: https://doi.org/10.1002/pip.845

. Y. Atwa, Distribution system planning and reliability assessment under high DG penetration. PhD Thesis, University of Waterloo, 2010.

. D. Das, Electrical Power Systems, 2007. New Age International Pvt Ltd Publishers.

. The General Electricity Company of Libya (GECOL). General Administration of the Medium Voltage Network, Operation Planning Department, Misurata Central Circle .Date of update 3/2018.